Neat cabling, reliable power

rack-mount power distribution units (PDUs)

Energy Management with PDU

A PDU guarantees a monitored and secured power supply to your valuable IT systems in the data centre, whether in the office or in the data centre.

In IT environments, clearly arranged power distribution units are mandatory. After all, servers run for several years and during this time it must be ensured that even in turbulent data centers a power plug is not even accidentally pulled at the rack. The devices presented here not only ensure power distribution, they also support remote control.

This means that individual outputs or sockets can be switched on and off via the network from any location. With Daisy Chaining, this is even possible via several interconnected PDUs and one IP address.

Need expert advice upfront?
PDU-Cyberpower
Filter
Outlets
Input
Loadable up to max.
Metered
Switched
No results for these filters!
CP-PDU20BHVIEC12R
PDU
9584-6912feefe241b565509531-58442ac60a6654e9f08e4619703d26e6def96df9_COPY__1NP_0000618_00G_FT_01_WS_A_1_

CyberPower PDU20BHVIEC12R supplies 12 connected servers, storages and other devices with power.

Show more
CP-PDU13401
PDU
9582-6912feefdc6f7136745538-be568d58b88dfe4ed1ffd4f5be7b30fb873f8f42_1NE_0000125_00G_FT_01_WS_E_1_

CyberPower PDU13401 versorgt 8 angeschlossene Server, Storages und andere Geräte mit Strom.

Show more
CP-PDU20BHVIEC8R
PDU
9586-6912feefea74b947455242-6e5f65a617c08cd2332e64009459c66ec6ae9f9d_1NE_0000128_00GD_FT_01_WS_E_1_
CyberPower PDU20BHVIEC8R supplies 8 connected servers, storages and other devices with power.
Show more
CP-PDU24004
PDU
9589-6912fef0146e3530459952-643ef370c7a73e2fd196f9097d6e8a87050df214_1NE_0000135_00GD_FT_01_WS_E_2__1_

CyberPower PDU24004 supplies power to 12 connected servers, storages and other devices. The device offers remote control of individual sockets via the network, allowing administrators to switch connected devices on and off from any location. The daisy chain function also makes it possible to monitor and control several interconnected PDUs via one IP address. Via the Ethernet module, the PDU communicates with the PowerPanel management software internally and via the Internet in real time for remote monitoring and configuration. Users can check the progress of the power status at any time via event logging and have notifications sent by e-mail, SMS or SNMP trap.

Show more
CP-PDU24005
PDU
9592-6912fef01eb65967872805-e75e2b7b55d0c6e7ee48da12058bf280a399ada6_1NE_0000137_00GD_FT_01_WS_E_2_

CyberPower PDU24005 supplies power to 10 connected servers, storages and other devices. The device offers remote control of individual sockets via the network, allowing administrators to switch connected devices on and off from any location. The daisy chain function also makes it possible to monitor and control several interconnected PDUs via one IP address. Via the Ethernet module, the PDU communicates with the PowerPanel management software internally and via the Internet in real time for remote monitoring and configuration. Users can check the progress of the power status at any time via event logging and have notifications sent by e-mail, SMS or SNMP trap.

Show more
CP-PDU41004
PDU
8600-6912fef02b3f7100614029-6a722c34565bb8bf32d7ddedc512416d8d7de69d_CP_PDU41004_front

CyberPower PDU41004 powers multiple connected devices from a UPS unit, generator or utility grid. The unit provides remote control of individual outlets over the network, allowing administrators to turn connected devices on and off from any location. The daisy chain feature also allows multiple interconnected PDUs to be monitored and controlled from one IP address. Through the Ethernet module, the PDU communicates with the PowerPanel management software internally and over the Internet in real time for remote monitoring and configuration. Users can check power status history at any time via event logging and have notifications sent via email, SMS or SNMP trap to.


Show more
CP-PDU41005
PDU
8622-6912fef0323f6835532613-621173ee3ebfc1ed87dbf7c3bb76b32320d793fe_CP_PDU41005_front

CyberPower PDU41005 powers multiple connected devices from a UPS unit, generator or utility grid. The unit provides remote control of individual outlets over the network, allowing administrators to turn connected devices on and off from any location. The daisy chain feature also allows multiple interconnected PDUs to be monitored and controlled from one IP address. Through the Ethernet module, the PDU communicates with the PowerPanel management software internally and over the Internet in real time for remote monitoring and configuration. Users can check power status history at any time via event logging and have notifications sent via email, SMS or SNMP trap to.


Show more
CP-PDU41405
PDU
8640-6912fef0363b2642009696-78fa0530e8d912f137bddaa51cc4926a268bc581_CP_PDU41405_front

CyberPower PDU41405 powers multiple connected devices from a UPS unit, generator or utility grid. The unit provides remote control of individual outlets over the network, allowing administrators to turn connected devices on and off from any location. The daisy chain feature also allows multiple interconnected PDUs to be monitored and controlled from one IP address. Through the Ethernet module, the PDU communicates with the PowerPanel management software internally and over the Internet in real time for remote monitoring and configuration. Users can check power status history at any time via event logging and have notifications sent via email, SMS or SNMP trap to.


Show more
Shows 8 of 15

Maximum flexibility for your data centre

Our PDUs accommodate every rack layout: mount them horizontally in a single rack unit or position them vertically behind the cabinet—whichever best uses the available space. (A suitably rated feed line is, of course, essential.)

Standard 1.5 mm² power cables safely deliver about 3,500 W per circuit; choosing a larger conductor cross-section adds an extra margin of safety for mission-critical rooms.

Simple, professional monitoring

A metered PDU reports real-time load via its built-in LCD. The display can be rotated for perfect readability in any mounting position, and its back-light colour is user-selectable—handy for visually grouping PDUs by power domain.

Integrated Ethernet modules provide remote supervision and real-time configuration. Event logging through a web browser or network connection lets you review and archive power metrics over time. Automatic alerts via e-mail, SMS, or SNMP trap keep you informed the moment thresholds are breached.

Although each unit operates reliably at ambient temperatures up to 60 °C, an optional environmental sensor can be added for continuous temperature and humidity monitoring—delivering an extra layer of protection for high-density racks.

Starline benefits

git-pull-request
Proven compatibility

We know which components work together because we test the connectivity extensively in advance.

chevrons-right
Wide range of products

We can offer you coherent alternatives in every storage category and are able to fulfill almost all product wishes.

user-check
Loyal partner

Our long-standing business relationships prove our loyalty to customers and suppliers.

Load more
Various PDU features
PDU models
Basic PDU

In the simplest version, it distributes the power in a structured manner - no more, no less. As a 19-inch multiple socket outlet with corresponding brackets for the server cabinet.

Metered PDU

A metered PDU displays the power currently being consumed by the connected devices. It shows this clearly on a small display or via remote access.

Switched PDU

With a switched PDU, individual ports can be switched on and off - even remotely via the network. In the event of an unexpected software error, the administrator can restart the server without being on site.

Switched Metered-per-output PDU

With this combination of the previous model features: This allows individual sockets to be controlled (Switched) and power consumption to be measured (Metered). The addition “Pro” makes it clear that measurement is possible per outlet.

ATS PDU models
Metered ATS PDU

This sophisticated PDU (ATS = Automatic Transfer Switch) automatically switches between two sources - such as different phases, connected UPSs or generators - if one of them should fail. This is particularly important in critical IT infrastructures, as it is capable of switching within a few milliseconds. As a metered model, the PDU also displays the power consumed.

Switched ATS PDU

This Automatic Transfer Switch PDU offers automatic switching of the inputs as described above, but also enables manual switching of the individual outputs.

Switched Metered-per-output ATS PDU

In this feature combination, the ATS PDU switches and measures each individual output manually and the two inputs automatically. This gives the user maximum control, reliability and energy efficiency, for example in high-end server rooms or for managed services.

Maintenance Bypass PDU models
IEC Bypass PDU

A Maintenance Bypass PDU (MBP) is connected between the input distribution board and the UPS. This allows the UPS to be bypassed without service interruption in the event of maintenance work - changing the battery, testing or replacing the UPS. These models use standard IEC connectors.

Bypass PDU with terminal block

A Maintenance Bypass PDU (MBP) is connected between the input distribution board and the UPS. This allows the UPS to be bypassed without service interruption in the event of maintenance work - changing the battery, testing or replacing the UPS. With these models, the input and output are connected via a terminal strip with installation cables. Depending on the model, single or multiple outputs are also available in IEC format.

Any questions? Please contact us.