Safeguard your data with UPS power

Uninterrupted and secure.

Zero-panic power continuity — CyberPower UPS solutions

Discover how to shut down your high-availability servers safely—or keep them running—when the mains go dark.

An uninterruptible power supply (UPS) delivers the reserve power required for a controlled shutdown of every connected system. Depending on battery capacity, it can also maintain limited operation for a defined period—from a few minutes to several hours. The right size depends entirely on your objectives:

  • Graceful shutdown – enough runtime to flush write caches and power servers down cleanly.
  • Extended uptime – additional reserves to keep critical services online for as long as possible.

CyberPower UPS units let you choose the exact autonomy your infrastructure demands, safeguarding data integrity and business continuity even in a complete power outage.

Need expert advice upfront?
CyberPower UPS product range
Filter
Technology
Phase input
Formfactor
Type & number of outlets
Autonomy time 50% load (minutes)
Autonomy time 100% load (minutes)
Apparent power
Active power
No results for these filters!
CP-900EPFCLCD
UPS
9373-6912feef2b04e485094578-a6defe7c9eae4f5e23ae13a6b2f27c79fb764e62_CP_900EPFCLCD_front

The CyberPower CP900EPFCLCD can be used to permanently protect workstations, standalone servers, NAS and network hardware. In regular operation, it supplies the connected systems with a pure sine wave and protects the incoming mains and signal lines from surges. In the event of a power failure, it continues to deliver uninterrupted power to the device being protected. Meanwhile, via USB, the CP900 signals the incident using PowerPanel management software and safely shuts down the connected server. In addition, PowerPanel displays scheduled shutdowns, can perform self-diagnostics, monitors power consumption values and displays the approximate bridging time. In continuous operation, CyberPower UPSs feature efficient operation and minimize energy costs with their GreenPower Bypass technology.


Show more
CP-OL1000ERTXL2U
UPS
8521-6912feef47a47469274289-c99b1e630a3944f65c356a33334286dd1223fbe5_CP_OL1000ERTXL2U_front

The OL Online Rackmount Series from CyberPower is ideal for servers, networks, workstations and other mission-critical applications that require the highest level of protection. With online double conversion design and no switchover time, it consistently and seamlessly provides a sine wave output voltage for critical loads. With Extended Runtime (XL) battery extensions, UPS bypass time can be extended accordingly. The optional Remote Management Card (RMCARD) enables remote control, management and monitoring of the UPS via standard web browsers.


Show more
CP-OL1500ERTXL2U
UPS
8533-6912feef52f2f427919174-3aa4b5977083079b6a2ea50cde757c12a96489a6_CP_OL1500ERTXL2U_front

The OL Online Rackmount Series from CyberPower is ideal for servers, networks, workstations and other mission-critical applications that require the highest level of protection. With online double conversion design and no switchover time, it consistently and seamlessly provides a sine wave output voltage for critical loads. With Extended Runtime (XL) battery extensions, UPS bypass time can be extended accordingly. The optional Remote Management Card (RMCARD) enables remote control, management and monitoring of the UPS via standard web browsers.


Show more
CP-OL2200ERTXL2U
UPS
9290-6912feef984b9317697448-fd202cc8ac47a7fbd68537185b81718e7fa55aee_1PE_0000770_00GD_3D_01_WS_E_1_

The OL Online Rackmount Series from CyberPower is ideal for servers, networks, workstations and other mission-critical applications that require the highest level of protection. With online double conversion design and no switchover time, it consistently and seamlessly provides a sine wave output voltage for critical loads. With Extended Runtime (XL) battery extensions, UPS bypass time can be extended accordingly. The optional Remote Management Card (RMCARD) enables remote control, management and monitoring of the UPS via standard web browsers.

Show more
CP-OL3000ERTXL2U
UPS
8548-6912feefa74e0365834432-68cfacf72791b2828ed94bc0186ad88b63c2ebe7_CP_OL3000ERTXL2U_front

The OL Online Rackmount Series from CyberPower is ideal for servers, networks, workstations and other mission-critical applications that require the highest level of protection. With online double conversion design and no switchover time, it consistently and seamlessly provides a sine wave output voltage for critical loads. With Extended Runtime (XL) battery extensions, UPS bypass time can be extended accordingly. The optional Remote Management Card (RMCARD) enables remote control, management and monitoring of the UPS via standard web browsers.


Show more
CP-OL6000ERT3UP
UPS
8570-6912feefb3c82077349358-e95d5127273286836af83e514fa21a712ae31659_CP_OL6000ERT3UP_front

The OL Online Rackmount Series from CyberPower is ideal for servers, networks, workstations and other mission-critical applications that require the highest level of protection. With online double conversion design and no switchover time, it consistently and seamlessly provides a sine wave output voltage for critical loads. With Extended Runtime (XL) battery extensions, UPS bypass time can be extended accordingly. The optional Remote Management Card (RMCARD) enables remote control, management and monitoring of the UPS via standard web browsers.


Show more
CP-RMCARD205
UPS
8667-6912fef09912d872226065-28b0e00a3df4237e7014d9eb01cca8701ce142b9_CP_RMCARD205_front

The Remote Management Card RMCARD 205 extends CyberPower UPSs via app for intelligent remote management. This allows the UPSs to be configured via standard web browsers or Network Management System (NMS). They can be remotely controlled, scheduled shutdowns or reboots can be scheduled and executed directly. It can also be used to send alerts. The admin can then monitor the UPS directly via email, SMS and SNMP trap. The model also supports the ENVIROSENSOR environmental sensor for monitoring temperature and humidity.


Show more
CP-UT850EG
UPS
8643-6912fef0a5341805239951-76669dfab981409a16c19affe01ce0723992705d_CP_UT850EG_front

The CyberPower UT850EG can be used to permanently protect workstations, standalone servers, NAS and network hardware. In regular operation, it supplies the connected systems with a pure sine wave and protects the incoming mains and signal lines from surges. In the event of a power failure, it continues to deliver uninterrupted power to the device being protected. Via USB, the PowerPanel management software signals an incident and safely shuts down the connected server. In addition, PowerPanel indicates planned shutdowns, can perform self-diagnostics, monitors power consumption values and displays the approximate bridging time. In continuous operation, CyberPower UPSs feature efficient operation and minimize energy costs with their GreenPower Bypass technology.


Show more
Shows 8 of 8

CyberPower UPS systems

Beyond delivering emergency power, the CyberPower units we supply also shield your infrastructure from line noise and voltage spikes on both power and signal paths. Each UPS continuously reports input-side power status to the host server, allowing the server to initiate an orderly shutdown the moment mains power is lost.

From the entry-level UT series to professional models for complex networks, Starline has a CyberPower UPS for every application—along with the full range of accessories such as remote-management cards, replacement batteries, and PDUs. An intuitive, no-cost management suite lets you fine-tune every UPS precisely to your operational requirements.

Starline benefits

git-pull-request
Proven compatibility

We know which components work together because we test the connectivity extensively in advance.

chevrons-right
Wide range of products

We can offer you coherent alternatives in every storage category and are able to fulfill almost all product wishes.

user-check
Loyal partner

Our long-standing business relationships prove our loyalty to customers and suppliers.

Load more
For the security of your data
CyberPower UPS - Frequently asked questions and answers
What are the benefits of a CyberPower UPS?

- Protection against data loss during power outages

- Protection of sensitive devices from voltage fluctuations

- Automatic shutdown of systems by the management software

How do you choose the right UPS for your system or network?

Consider the power of your devices (in watts or VA respectively) and choose a UPS with sufficient capacity. CyberPower offers an online calculator to help you choose. 

What is the difference between line-interactive and online UPS?

Line-interactive UPS: Regulates slight voltage fluctuations without using batteries. The UPS is virtually on standby during normal operation. 
Online UPS: Offers maximum protection thanks to continuous double conversion technology. They are therefore permanently in operation.

What factors influence the runtime of a UPS?

- Battery capacity
- Total power of the connected devices
- Battery condition

How long does a battery charge of a CyberPower UPS last?

The runtime depends on the battery capacity (with built-in battery or optional additional battery) and the attached load. You can call up corresponding predictions with the CyberPower runtime calculator

What is the difference between a UPS with a pure sine wave and a modified sine wave?

Pure sine wave: A UPS with a pure sine wave generates an alternating current whose voltage curve has a perfect sinusoidal shape. Energy-saving power supply units with active power factor correction (PFC) require a pure sine wave source.

Modified sine wave: A UPS without a pure sine wave, often referred to as a modified sine wave, generates a voltage curve that is not perfectly sinusoidal. With this type of UPS, the peaks of the sine wave are flattened or cut off to save costs and increase efficiency. Non-inductive loads and insensitive electronics are suitable for such UPS

How do I install a CyberPower UPS correctly?

Install the UPS in a dry environment, connect the devices and charge the battery at least 8 hours before first use.

Where should a UPS ideally be installed?

In a well-ventilated room, away from direct sunlight or heat sources.

How do I calculate the total power requirement of my connected devices?

Simplified: Add up the Watt or VA specifications of all the devices concerned. CyberPower also offers a calculator for this purpose.

Any questions? Please contact us.

BW
Bernd Widmaier
Sales

Sales manager and expert in vertical markets and in Mac, video storage and media streaming.